Introduction:
Amgenix International, Inc., USA has developed a novel rapid diagnostic test to determine the immune status of HIV/AIDS patients in resource poor settings so that the need for anti-retroviral therapy can be established or to identify those whose current treatment may need changing.

 

The Test:
The OnSight™ – CD4 STATUS One-Step Test measures proteins that correlate to CD4 counts. The test, which is a VISUAL assay, employs a test line with a cutoff, which is subject to some degree of interpretation by the user as to when the test line disappears which is indicative of a negative result. As it is difficult to have an exact cutoff point using lateral flow technology, the tests stated cutoff is actually in a range, in this case equivalent to a CD4 count of 200 +/- 25 CD4 cells which is where the test line signal will in most cases disappear from the OnSight™ – CD4 STATUS test device. Based on outside evaluations to date, the OnSight™ – CD4 STATUS Test is showing a correlation of approximately 89 percent versus flow cytometry. It is also important to understand that there is a fair degree of variation in test results from one brand of flow cytometer to another brand even when using the same test sample and from one CD4 count to another CD4 count even on the same sample when using the same equipment so any comparison of results between theOnSight™ – CD4 STATUS Test and flow cytometry should take into account that variation.

  

Test Results for the OnSight™ – CD4 STATUS Test:

 

Sample Number

CD4 Count

Viral Load

OnSight™ – CD4 STATUSTest Type

OnSight™ – CD4 STATUSTest Results

Date Run

 

 

 

 

NOTE:
Negative = No Test Line
Positive = Any visible Test Line

 

0005-041-01472

1000

 

OS200

Positive

07/01/07

0006-041-01825

225

 

OS200

Negative

07/01/07

0008-041-00640

174

 

OS200

Negative

07/01/07

0008-214-02462

528

 

OS200

Positive

07/01/07

0009-041-01357

354

 

OS200

Positive

07/01/07

0006-041-00754

994

63

OS200

Positive

09/05/07

0008-041-01001

599

188

OS200

Positive

09/05/07

0008-214-02455

200

5730

OS200

Positive

09/05/07

0009-041-01333

554

<25

OS200

Positive

09/05/07

0009-041-01345

376

<50

OS200

Positive

09/05/07

0010-258-02458

400

1640

OS200

Positive

09/05/07

0006-041-01826

402

<50

OS200

Positive

09/24/07

0009-096-01781

451

800

OS200

Positive

09/24/07

0009-214-01609

501

<50

OS200

Positive

09/24/07

0010-214-00041

456

15679

OS200

Positive

09/24/07

0005-041-01454

278

13211

OS200

Positive

11/06/07

0005-041-01695

301

6629

OS200

Positive

11/06/07

0006-041-00772

254

26801

OS200

Positive (very weak)

11/06/07

0006-041-01524

256

<50

OS200

Positive (very weak)

11/06/07

0007-041-01775

205

70

OS200

Negative

11/06/07

0008-041-00993

226

4972

OS200

Negative

11/06/07

0009-214-01940

301

39652

OS200

Positive

11/06/07

145719

1165

N/A

OS200

Positive

10/08/07

145721

920

N/A

OS200

Positive

10/08/07

145723

1012

N/A

OS200

Positive

10/08/07

145725

578

N/A

OS200

Positive

10/08/07

145726

641

N/A

OS200

Positive

10/17/07

146106

923

N/A

OS200

Positive

10/17/07

146108

880

N/A

OS200

Positive

10/17/07

IN 01

457

N/A

OS200

Positive

12/06/07

IN 02

142

N/A

OS200

Positive (very weak)

12/06/07

IN 03

304

N/A

OS200

Positive

12/06/07

IN04

604

N/A

OS200

Positive

12/20/07

IN05

287

N/A

OS200

Negative

12/20/07

IN06

99

N/A

OS200

Positive (very weak)

12/20/07

IN07

214

N/A

OS200

Positive (very faint)

12/20/07

IN08

537

N/A

OS200

Positive

12/20/07

IN09

634

N/A

OS200

Positive

12/20/07

IN10

225

N/A

OS200

Positive (weak line)

12/20/07

IN11

32

N/A

OS200

Positive

12/20/07

IN12

171

N/A

OS200

Positive (very faint line)

12/20/07

IN13

193

N/A

OS200

Positive (very faint line)

12/20/07

IN14

395

N/A

OS200

Positive

12/20/07

IN15

384

N/A

OS200

Positive

12/20/07

IN16

103

N/A

OS200

Negative

12/20/07

IN17

639

N/A

OS200

Positive

12/20/07

SA1

133

N/A

OS200

Positive

03/10/08

SA2

176

N/A

OS200

Positive

03/10/08

SA3

211

N/A

OS200

Positive

03/10/08

SA4

222

N/A

OS200

Positive

03/10/08

 

Results in RED are discordant
All results at 200 +/- 25 CD4 cells were considered positive based on the tests low end cutoff

 

N = 50

Correlation to Flow Cytometry = 89.1 %

 

Please Note:
Results for the OnSight™ – CD4 STATUS Test are reported as either Positive when a colored band of any intensity is seen in the Test area of the device or Negative when no colored band is visible in the Test area. As the amount of CD4 Equivalent proteins approaches the dynamic cutoff for the test which is approximately 200 +/-25 CD4 cells, the colored band in the Test area of the device will become lighter and lighter until it disappears at approximately 200+/-25 CD4 cells

 

Conclusion:
The OnSight™ – CD4 STATUS Test is producing results so far that would indicate the test would be clinically useful in determining the immune status of an HIV/AIDS infected person in resource poor settings where standard tests such as flow cytometry are; unavailable, unaffordable or where the need for test results are time sensitive.

 